Categories

Hot Products

Low Voltage Switchgear

12kV Combined Switchgear

12kV Combined Switchgear

General 1.Rating: Rated voltage 3~12KV , rated current reach to 630A for load break switch and 125A for combined switchgear . 2.Application :ring main unit switchgear mainly applicable in urban power grid construction and renovation project. industrial and mining enterprises. high-rise buildings......

General

1.Rating: Rated voltage 3~12KV , rated current reach to 630A for load break switch and 125A for combined switchgear . 
2.Application :ring main unit switchgear mainly applicable in urban power grid construction and renovation project. industrial and mining enterprises. high-rise buildings and communal facilities .For power distribution .controlling and protection on electric equipment as the loop power supply unit or terminal equipment.12kv switchgear also can be installed in preloaded substation. 
3.Feature: Equipped with vacuum load switch and spring operating mechanism which can be operated by hand or electric. Earthing switch and insulating switch are equipped with hand operating mechanism .With small volume and high security .
4. Standard: IEC60420

Working Conditions
1. Ambient air temperature: -15℃~+40℃. Daily average temperature:≤35℃. 
2.Altitude: ≤1000m.
3.Relative humidity : Daily average≤95% ,daily averange of vapour pressure≤2.2kpa Monthly average≤90%,monthly averange of vapour pressure≤1.8kpa. 
4.Earthquake intensity: ≤magnitude 8.
5.12kv switchgear applicable in the places without corrosive and flammable gas.
Note: Customized products are available

 

Main technical Parameter (refer to sheet 1 )
图1_副本1.jpg


Loop power supply principle
The loop power supply is composed of three basic unit to separate any one of the failure line and ensure the continuous power supply through the other unit. The branch line for the user could separated and protect the transformer which could facilitate the maintenance. The loop power supply could be expanded as per the user's requirements to form various protection plans. Picture 1

图2_副本2.jpg

 

Feature
1.8MF material adopted for the switchgear ,modular holes available with E=200. 
2.Switch disconnector ,vacuum load breaker switch, earthing switch and the switchgear door reliably interlocked ,which could avoid miss operation. 
3.Both manual and automatic operation are available. 
4.There is leas sealed pin at the door of measurement chamber and meter chamber . 
5.Prompt tripping could be realized to protect the equipments. 
6.The design facilitate the operation at the front panel and the switchgear could be installed alongside the wall.
7.The switchgear is featured for its complete interlocking function: the load break switch could be operated to the making status when the switchgear door is closed and locked and the earthing switch to the making position. When the earthing switch is at making status, input the insulation clapboard to its position, the switchgear door then, could be operated. 
8.The Vacuum arc-extinguishing chamber and fuse are reliably connected. So as the fuse & switchgear door and insulation clapboard & the switchgear door .